Kangaroo Joey Pump Set with Flush Bag Instructions: A Comprehensive Guide
This guide details the Kangaroo Joey enteral feed and flush pump system, covering set loading, priming, programming, and troubleshooting. Utilize this manual for safe and effective operation.
Understanding the Kangaroo Joey Pump System
The Kangaroo Joey enteral feed and flush pump is designed for delivering nutrition and medications to patients unable to take them orally. This system offers versatility through both feed-only and feed-and-flush set options, catering to diverse patient needs. It’s a pole-clamp mounted device, providing controlled delivery at rates between 0-400mL/hr, adjustable by the user.
Key to its functionality is the ability to integrate with specialized feeding sets, including those equipped with a flush bag for intermittent flushing to maintain patency of the feeding tube. The pump’s interface allows for precise programming of feed rates, volumes, and flush intervals. Understanding the system’s components and operational modes – including EZ PUMP for continuous feeding – is crucial for effective patient care.

Safety features are integrated, requiring careful adherence to priming procedures and set usage limits (typically 24 hours). Proper operation, as outlined in this user guide, ensures accurate delivery and minimizes the risk of complications.
Components of the System
The Kangaroo Joey enteral feeding system comprises several key components. Firstly, the Kangaroo Joey pump itself, a pole-clamp mounted device, serves as the central control unit. Secondly, the feeding set is crucial; options include feed-only sets (B) and feed and flush sets (C), the latter incorporating a dedicated flush bag.
A distal end of the feeding set (A) connects directly to the patient’s feeding tube. Additional necessities include a 60cc syringe for manual flushing when needed, and a backpack or IV pole for pump portability. The system requires careful loading of the set, avoiding overstretching of the tubing.

The pump’s door must be securely closed for proper operation, triggering a “Set Loaded” confirmation. Understanding the function of each component – from the pump’s interface to the specialized feeding set – is essential for safe and effective enteral nutrition delivery. Proper component interaction ensures accurate and reliable feeding.
Feed Only vs. Feed and Flush Sets
Kangaroo Joey systems offer flexibility with two primary feeding set types: feed-only and feed and flush sets. Feed-only sets (B) are designed solely for delivering enteral nutrition, simplifying the setup for continuous or bolus feedings without intermittent flushing. These are ideal when flushing isn’t a frequent requirement.

Conversely, feed and flush sets (C) integrate a dedicated flush bag, enabling convenient and controlled administration of flush solutions. This is particularly beneficial for maintaining patency of the feeding tube, clearing medication residue, or providing hydration between feedings. The integrated flush capability enhances the pump’s versatility.
Choosing the appropriate set depends on the patient’s needs and the prescribed feeding protocol. Feed and flush sets are advantageous when regular flushing is necessary, streamlining the process and reducing the need for manual intervention. Understanding these distinctions ensures optimal pump utilization and patient care.
Initial Setup and Safety Precautions
Prior to initiating therapy with the Kangaroo Joey enteral feed and flush pump, meticulous setup and adherence to safety precautions are paramount. Begin by ensuring the pump is placed on a stable surface, ideally an IV pole, and connected to a reliable power source. Inspect the pump and all components for any visible damage before use.
Carefully load the selected feeding set – either feed-only or feed and flush – following the manufacturer’s instructions. Avoid overstretching the tubing during loading. Always verify the correct set type is used based on the prescribed feeding regimen. Close the pump door securely; the pump should indicate “Set Loaded” upon successful detection.
Crucially, never exceed the pump set’s usage limit of 24 hours. Regularly inspect the tubing for leaks or kinks. Always follow proper hygiene practices when handling the feeding set to prevent contamination. Familiarize yourself with the pump’s error codes and alarm functions.

Loading the Feed and Flush Set

Properly loading the Kangaroo Joey feed and flush set is essential for accurate and safe delivery of nutrition. Begin by carefully removing the set from its packaging, ensuring the distal end remains sterile. Gently insert the set’s connector into the pump’s designated loading port, avoiding any forceful insertion that could damage the connection.
Distinguish between feed-only and feed and flush sets; the latter incorporates an additional port for flush solution. Ensure the correct set is selected based on the prescribed feeding protocol. Once connected, close the pump door firmly. The pump will automatically detect the set and display “Set Loaded” on the screen, confirming successful loading.
Avoid overstretching the tubing during the loading process, as this can compromise its integrity. Inspect the connection for any leaks or disconnections. If the pump fails to recognize the set, re-check the connection and ensure it’s fully seated. Refer to the pump’s manual for detailed diagrams and troubleshooting tips.
Prime Pump Function: Step-by-Step Instructions
Priming the Kangaroo Joey pump set eliminates air bubbles, ensuring accurate delivery and patient safety. Begin by confirming the feed and flush set is securely loaded. Press the “PRIME PUMP” button on the pump’s control panel. Subsequently, select “AUTO” to initiate the automated priming sequence.
The pump will automatically draw fluid through the tubing, purging any air present. Observe the tubing carefully, ensuring all air bubbles are expelled before the priming cycle completes. This process typically takes a few minutes, depending on the set’s length and the fluid’s viscosity.
Monitor the priming process closely. If air bubbles persist after the automated cycle, manually prime the set by gently squeezing the tubing until all air is removed. Once primed, the pump is ready for programming and initiating the feeding regimen. Always verify complete priming before commencing therapy.
Auto-Priming Procedure
Auto-priming simplifies pump set preparation on the Kangaroo Joey. After loading the feed and flush set and ensuring secure connections, initiate the process by pressing the “PRIME PUMP” button. Then, select the “AUTO” option; the pump will begin automatically drawing fluid through the tubing.

During auto-priming, the pump delivers a pre-programmed volume of fluid, effectively removing air from the entire system. Closely observe the tubing, verifying that all air bubbles are eliminated. The pump will typically pause automatically once priming is complete, indicated by a visual or auditory signal.
Important: Do not interrupt the auto-priming cycle unless absolutely necessary. If interruptions occur, restart the process. Post-priming, visually inspect the tubing for any remaining air. Successful auto-priming is crucial for accurate and safe enteral feeding with the Kangaroo Joey.
Programming the Kangaroo Joey Pump for Feed and Flush
Programming the Kangaroo Joey for feed and flush requires precise settings. Begin by entering the total daily feed volume. Next, program the delivery rate, specifying the amount of formula delivered per hour. The pump allows for variable rate schedules, accommodating individual patient needs.
To activate the flush function, access the flush volume and interval settings. Input the desired flush volume – typically water – and the frequency at which flushes should occur. This prevents occlusion and maintains tubing patency. The pump supports intermittent flushing schedules.
Utilize the pump’s intuitive interface to confirm all programmed parameters before initiating therapy. Double-check the feed rate, total volume, flush volume, and interval. Accurate programming is essential for delivering the prescribed nutritional support safely and effectively with the Kangaroo Joey.
Adjusting Flush Volume and Interval
Adjusting flush volume and interval is crucial for maintaining feeding tube patency and preventing occlusion. Press the “ADJUST FLUSH” button to access these settings on the Kangaroo Joey pump. The pump allows customization of both parameters to meet individual patient requirements.

Flush volume typically ranges from 5 to 60 mL, depending on tubing diameter and formula viscosity. Smaller volumes are suitable for narrow-bore tubes, while larger volumes may be needed for thicker formulas. The interval determines how often the flush is administered – options range from every 30 minutes to several hours.
Consider the patient’s tolerance and feeding schedule when setting the interval. Frequent flushes can interrupt feeding, while infrequent flushes may not adequately prevent occlusion. Regularly assess the feeding tube for signs of blockage and adjust the flush settings accordingly for optimal performance.
Utilizing the Resume In Feature
The “Resume In” feature on the Kangaroo Joey pump provides a convenient method to temporarily pause feeding delivery without completely stopping the pump. This is particularly useful during patient care activities like medication administration or vital sign checks, minimizing workflow disruptions.
To utilize this function, press the “Resume In” button. The pump will pause the feed, but continue to monitor the programmed delivery rate. This ensures a swift and accurate resumption of feeding when the button is pressed again. The remaining feed volume is preserved, preventing wasted formula.
This feature is ideal for intermittent feeding schedules or when brief interruptions are anticipated. It eliminates the need to reprogram the pump after each pause, saving time and reducing the risk of errors. Always confirm the pump has resumed feeding at the correct rate after using “Resume In”.
EZ PUMP MODE: Continuous Feeding Operation
EZ PUMP MODE on the Kangaroo Joey pump offers a simplified, continuous feeding option, ideal for patients requiring uninterrupted nutrition delivery. This mode is specifically designed for use with the pole clamp and operates as a limited, continuous function;
When activated, EZ PUMP MODE delivers a constant flow rate, set by the user between 0-400mL/hr, without the Variable Total Body Delivery (VTBD) option. This means the pump will feed non-stop until manually paused or stopped by the clinician. It’s a streamlined approach for consistent nutritional support.
Before initiating EZ PUMP MODE, ensure the feed set is properly primed and the pump is securely mounted. Regularly monitor the infusion site and tubing for any signs of occlusion or leakage. Remember, this mode lacks the programmed interruption features of standard modes, requiring diligent observation.
Re-Priming the Pump Set
Re-priming the pump set is crucial to maintain accurate delivery and prevent air from entering the feeding line, especially after interruptions or if air bubbles are detected. This process ensures consistent and safe enteral nutrition for the patient.
To re-prime, access the pump’s menu and select the “PRIME PUMP” function, then choose “AUTO”. The pump will automatically initiate the priming sequence, drawing fluid from the feed or flush source through the tubing, eliminating any air pockets. Closely observe the tubing during priming, confirming complete removal of air bubbles before resuming feeding.
If the auto-prime function fails, manual priming may be necessary. Disconnect the feeding bag, and using a syringe, gently infuse fluid through the tubing until it’s completely filled and free of air. Reconnect the feeding bag and verify proper flow before resuming. Always refer to the Kangaroo Joey user manual for detailed instructions.
Pump Set Usage Limits and Replacement
Kangaroo Joey pump sets are designed for single-patient use and have specific usage limitations to ensure patient safety and maintain optimal performance. Adhering to these guidelines is paramount for preventing complications and ensuring accurate nutrient delivery.
Pump sets should not be reused after 24 hours of initial usage, even with thorough cleaning. Prolonged use can compromise the tubing integrity, leading to leaks, cracks, or bacterial contamination. Regularly inspect the set for any signs of damage, such as kinks, punctures, or discoloration.
Replace the pump set immediately if any of these issues are observed. Additionally, replace the set if it has been exposed to any potentially contaminating substances. Proper disposal of used pump sets, following hospital protocols for biohazardous waste, is essential. Consistent replacement contributes to a safe and effective enteral feeding experience.
Troubleshooting Common Issues
Encountering issues with the Kangaroo Joey pump is possible; however, many can be resolved with simple troubleshooting steps. If the pump displays an error code, consult the “Understanding Error Codes” section of this guide for specific instructions. A common issue is occlusion, where the feed is interrupted due to a blockage.
First, check the tubing for kinks or compression. If no obstruction is visible, attempt to re-prime the pump set. If the pump fails to prime, ensure the feed bag is adequately filled and the tubing is not clamped. For persistent occlusion, replace the pump set as the tubing may be internally blocked.
If the pump isn’t delivering the programmed rate, verify the programming settings and ensure the battery is sufficiently charged. If problems persist, contact biomedical engineering or the manufacturer’s support line for assistance. Always prioritize patient safety and discontinue feeding if issues cannot be quickly resolved.
Cleaning and Maintenance
Regular cleaning and maintenance are crucial for ensuring the Kangaroo Joey pump’s optimal performance and longevity. The pump’s exterior should be wiped down with a damp, non-abrasive cloth and mild detergent. Avoid getting moisture inside the pump housing. Do not immerse the pump in water or any other liquid.
The pump set is single-use only and should be discarded after each patient or 24 hours of use, whichever comes first. Do not attempt to sterilize or reuse pump sets. Inspect the pump and tubing regularly for any signs of damage, such as cracks or leaks. If damage is detected, replace the affected components immediately.
Periodically check the battery’s performance and replace it when necessary. Follow the manufacturer’s guidelines for battery disposal. Proper maintenance extends the pump’s lifespan and ensures accurate and reliable delivery of enteral nutrition. Keep the pump stored in a clean, dry environment when not in use.
Understanding Error Codes
The Kangaroo Joey pump utilizes error codes to indicate specific issues requiring attention. These codes are displayed on the pump’s screen, providing valuable diagnostic information; A common error, “Set Occlusion,” signals a blockage within the feeding set, potentially due to kinking or compressed tubing. Addressing this involves gently straightening the tubing or checking for obstructions.

“Air in Set” indicates air bubbles detected within the system, requiring re-priming of the pump set to ensure accurate delivery. “Low Battery” prompts immediate charging or battery replacement to prevent interruption of feeding; Other codes may relate to pump malfunctions or programming errors.
Consult the comprehensive user guide for a complete list of error codes and their corresponding solutions. Ignoring error codes can compromise patient safety and feeding accuracy. Always address errors promptly and follow the recommended troubleshooting steps. If an error persists, contact a qualified biomedical technician or the manufacturer’s support team.
Powering Down the Pump

Properly powering down the Kangaroo Joey pump is crucial for preserving battery life and ensuring system stability. To initiate shutdown, first ensure all feeding has completed and the pump set is disconnected or appropriately clamped to prevent unintended delivery. Navigate to the main menu using the pump’s control panel.
Select the “Power Off” or “Shutdown” option, typically indicated by a power symbol. The pump will display a confirmation message before completely powering down. Avoid abruptly disconnecting the power source while the pump is actively running, as this could potentially corrupt programming settings or damage internal components.
When using battery power, regularly check the battery level and recharge as needed. Store the pump in a clean, dry environment when not in use. Always refer to the user manual for specific instructions related to your pump model. Following these steps ensures the longevity and reliable operation of your Kangaroo Joey pump.